Acoustic Windows

AC-90 — Certified Rw 45 dB · asymmetric glazing · sealed cavities

Questions on this system — sizes, glazing, lead time?

Ask on WhatsApp
Double-glazed window in the showroom, the park outside

AC-90

For streets, airports and highway frontages that refuse to stay quiet at night.

Certified Rw 45 dB · asymmetric glazing · sealed cavities

Configurations
10
Glazing options
6
Lead time
35–45 days
Warranty
15 yr

Configurations

10

Glazing options

6

Lead time

35–45 days

Warranty

15 yr

Both documents are free — quoted against your project within 24 hours.

123

AC-90 frame section, thermal-break build. Photographed section, hardware and installation detail below.

What the section drawing decides

High-end custom is decided in the section drawing, not the brochure. These four layers are held to specification on every AC-90 unit we ship.

01

Sealed dual cavity

Frame cavity is sealed because an open cavity would bridge the two glass leaves and give the sound a path through.

02

Opening type follows the room

Tilt-turn, casement or fixed: a bedroom needs the closed casement, a study can take tilt-turn. The glass does the work either way.

03

Asymmetric laminated, 24-42 mm

Two lites differ in thickness on purpose. A symmetric build would ring; the asymmetry is what holds Rw 45 dB.

04

EN ISO 10140-2 laboratory certified

Certification is on the configuration, so the pane schedule travels with the report. Typical sites: arterial roads, airport radius, rail frontage.

Technical detail

The section, the hardware and the fixings — photographed, not rendered. This is the level of detail your drawing office specifies against and your site crew installs to, on every unit that leaves the line.

01

Profile cross-section

Sealed dual cavity, because an open cavity would bridge the two glass leaves and hand the sound a path straight through. The cavity is closed for the same reason the glass is asymmetric.

Frame

Sealed dual cavity

Gasket

Acoustic, continuous

Glazing

Asymmetric laminated, 24–42 mm

Certification

Rw 45 dB configuration

Cut aluminium profile sections held in a gloved hand beside a PA66 GF25 thermal break sample
Profile sections cut open: the thermal break, the chambers and the glazed edge read as three separate things.
Thermal break bar visible in the window frame cross section
The continuous PA66 break bar isolates the outer and inner aluminium.
Multi-chamber aluminium profile cross section with the insulation bar cut through
Chambers in the profile cross section — stiffness and drainage run through the cavity layout, not the wall thickness alone.
Thermally broken aluminium profile with the polyamide bridge
The polyamide bridge breaks the conductive path that would otherwise run across the frame.
Profile cross sections and a glazed edge on the showroom display rack
Sections on the same platform, sized for the leaf load and the threshold.
Thermal break bar detail on the extrusion line
Thermal break bar, second detail — continuous PA66 from the extrusion line.
02

Hardware

Tilt-turn, casement or fixed: a bedroom needs the closed casement, a study can take tilt-turn. The hardware follows the room, the glass does the acoustic work either way.

Openings

Tilt-turn / casement / fixed

Decision

Set by the room, not the glass

Gasket

Acoustic, continuous

Check

Cycled as the leaf is glazed

Multi-point locking bolt points on a door leaf edge
Multi-point locking — the handle drives bolt points top, bottom and on the meeting stile, not one edge.
Window handle with base plate and strike set and fixing screws
Handle, base plate and strike set — the full set, fitted and cycled before dispatch.
Dark lever handle on a white door leaf
Key-operated handle for ground-floor and security specifications.
Metal lever handle catching the light on a timber door
Metal finish for clean, high-traffic interior positions.
Steel entrance door with a multi-point lock and keypad
Strike and fixings match the handle set; nothing is improvised on site.
Handle sets laid out for the fitting line
Every handle set is matched to the sash before the unit is built.
Gloved hands fitting a corner bracket and hardware into an aluminium profile
Fitted on the line, not on site — the corner bracket and its fasteners go in as one operation.
Corner bracket and hardware components held in a gloved hand
The corner bracket is what ties the joint together; it is cut and drilled to match the profile it drives.
03

Installation

Factory-assembled and pre-glazed, so the tolerance work is done under a roof. On site the build is a three-zone detail — air, insulation, weatherproofing — and every crate arrives with the install guide and the sealant schedule for that market.

Arrives

Factory-assembled

Detail

3-zone: air / insulation / water

Guide

Per-crate install sheet

Sealant

Scheduled per market

Ivy-clad elevation with the window openings left in view
The opening condition on a real elevation — each layer does one job and the details are not mixed.
Gasket line being run into the sash profile
Every glazed unit is sealed along the gasket line before it leaves the shop.
Extruded gasket stock racked in the factory store
Gasket is stocked as a schedule, not a habit — the compound and the section are named per market.
The same gasket run seen across the line
Pre-treatment and powder coat — every profile runs the surface line before assembly.
Machinist cutting a component on the workshop line
The workshop line — components cut, machined and checked at the quality gate, before crating.
Die casting press forming the hardware components
Hardware is cast in-house, so the cam and gear match the profile it drives.

The system in short

Acoustic windows are specified to a measured figure rather than a style: asymmetric laminated glazing, sealed frame cavities and a dedicated acoustic gasket cut the sound that reaches the room. AC-90 is certified to Rw 45 dB — a 47 dB glazing unit in a dual-cavity frame — for arterial roads, airport radii and rail frontages.

Acoustic configurations pair asymmetric laminated glazing with a sealed dual-cavity frame and a dedicated acoustic gasket — the same recipe used in airport-adjacent residential projects, laboratory certified to Rw 45 dB with a 47 dB glazing unit.

The frame is a dual-cavity build and the glazing is asymmetric laminated — heavier pane on the outside, lighter on the inside, which is what breaks the resonance a matched pair would pass. Configured per position after a noise survey, quoted to the indoor target level, not to a catalogue figure.

AC-90 installed view
AC-90 — Acoustic Windows
AC-90 detail
AC-90 — detail

Models and sizes

Every AC-90 ships as one of the configurations below — specify by model code in your window schedule and it quotes line by line.

AC-90 TILT

  • Tilt-turn acoustic sash
  • 47 dB laminated IGU

AC-90 CAS

  • Hinged acoustic sash
  • 47 dB laminated IGU

AC-90 FIXED

  • Fixed acoustic panel
  • 47 dB laminated IGU

AC-90 CORNER

  • Fixed corner acoustic unit
  • 47 dB laminated IGU
AC-90 configurations in place
AC-90 — configurations in place

Specifications

Acoustic
Rw 45 dB certified (47 dB glazing units)
Glazing
Asymmetric laminated, 24–42 mm total
Frame
Sealed dual cavity, acoustic gasket
Opening
Tilt-turn, casement or fixed
Typical sites
Arterial roads, airport radius, rail frontage
Standards
EN ISO 10140-2 laboratory certified
AC-90 profile and glazing detail
AC-90 — profile and glazing detail

Material & craft

The layers held to specification on every AC-90 unit — the section drawing above, written out.

Glazing unit

Glazing unit

A 47 dB laminated IGU with a 24–42 mm asymmetric core — the two different glass masses break the resonances a symmetric pane carries through.

Frame build

Frame build

A sealed dual-cavity frame with the dedicated acoustic gasket; airtightness Class 4 is part of the acoustic build, because an unsealed joint is a leak in the rating.

Certification

Certification

Rw 45 dB laboratory certified per EN ISO 10140-2 — the figure on the data sheet is the figure from the test report.

What it's worth to you

Acoustic Windows installed on a residential elevation

A certified number instead of a claim: the noise survey sets the figure, the glazing mass is tuned to it, the test report proves it.

It rides the 70/75 mm platform — the quiet elevation and the standard elevation share one frame line and one schedule.

A 70 dB arterial street lands under 25 dB at the sash with the certified configuration.

Specify Acoustic Windows

Send the project location, the opening sizes and the finish. Drawings, window schedules or a specification can be attached — quoting is done against the drawings, not a price list.

Request a quotation

Fields marked * are required. Drawings, CAD or a window schedule can be attached — up to 5 MB.

Products of interest
Acoustic Windows
Attach drawing / schedule (dwg, pdf, xls — max 5 MB)

Guaranteed response within 24 hours, every inquiry. No price lists are shared outside the quotation.

Where it is specified

The sites we build this system for, and what the schedule changes in each one.

Arterial road frontages

Typical 70 dB street traffic lands under 25 dB at the sash.

Airport radius

Asymmetric laminated core tuned to the dominant noise band.

Rail frontage

Sealed cavity plus acoustic gasket for low-frequency content.

City-centre apartments

High-rise street view without the street noise.

Hospitality lobbies

Open-plan rooms next to traffic — the glazing does the zoning.

Options and finishes

Acoustic
Rw 45 dB certified (47 dB glazing units)
Glazing
Asymmetric laminated, 24–42 mm total
Frame
Sealed dual cavity, acoustic gasket
Opening
Tilt-turn, casement or fixed
Typical sites
Arterial roads, airport radius, rail frontage

Finish

Anodised Natural

Anodised Silver

Anthracite · RAL 7016

Graphite · RAL 7024

Jet Black · RAL 9005

Traffic White · RAL 9016

Cream · RAL 1015

Champagne · RAL 1019

Ash Natural

Walnut Dark

Bronze

Copper

View all finishes

Design features

Rw 45 dB laboratory certified (EN ISO 10140-2)

Asymmetric laminated glazing, 24–42 mm total

Sealed dual-cavity frame, acoustic gasket

Tilt-turn, casement or fixed actions

Airtightness Class 4 as part of the acoustic build

Noise-survey-driven glazing mass selection

Glass build

Two choices set what the glass does in a AC-90: which coating is on it, and what fills the cavity. The coating sets the solar figure. The gas moves the U-value and leaves the solar figure where it was — which is why the two are decided separately. The values below are published by the glass manufacturers for the build named; they are centre-of-glass figures, and the whole-window value for a configuration is read from the report that covers it.

BuildSHGCU, centre of glassWhere it is chosen
LoE-180, argon0.690.26High solar gain, cold climate
LoE-272, argon0.410.25Balanced, the usual default
LoE-366, argon0.270.24Solar control, west and south glass
LoE-366 with LoE-i89 on #4, argon0.270.20Solar control with the lowest U-value

NFRC centre-of-glass values for a 3/4 in two-pane unit with 3 mm lites and a 13 mm argon cavity. The spacer is the third lever and behaves differently again: it works at the edge of the unit, so it shows in the whole-window value rather than here.

Full glass performance tables, including air against argon and EN 673 values →

Buying & delivery

The commercial terms behind the AC-90 — minimum order, quotation, payment, packing and warranty — are the same on every quotation and sit on the commercial terms for a certified acoustic build. Buying to resell, or to fabricate the line yourself? how an acoustic unit is supplied covers the supplier view of the same schedule.

Request a quote for this system
Lead time
35–45 days from approved shop drawings. Assembly, glazing and quality control sit inside the quoted lead time, not on top of it.
Standards on this system
Laboratory certified to EN ISO 10140-2 for the Rw 45 dB configuration. The assembly answers SANS 613 for wind, water and air, with the acoustic figure certified against the configured unit rather than a catalogue sample.Source documents: ISO 10140·SANS 613
Documents and crating
Hardware and glass schedules ship in the shop drawing package, free, within three working days of approved architectural drawings. The acoustic certificate is issued against the configured unit. Test reports are issued on request.

Documentation

Data sheet

System specifications, model codes and glazing schedule, as a PDF.

Brochure

Full-range presentation for tender packs and client meetings.

CAD sections & BIM families

Section blocks and families for inclusion in project documentation.

Ask for it

Specification clauses

Draft specification text for the drawing package, per system.

Ask for it

RFQ template

The inquiry sheet our quote team needs to answer within 24 hours.

Open the downloads

Confirm before the order is placed

Six items hold up an order on the AC-90 more often than anything else. None of them is decided here; each one has to be settled on the project side before the drawing set is frozen.

Rough opening, not frame size

Confirm the structural opening and the reveal build-up. The frame is ordered to the approved drawing, and the drawing is what the quotation is built from.

The opening is quoted before the render and the closing detail, then the reveal takes back the clearance.

Glass build

Confirm pane thickness, coating, spacer and cavity gas as one line. The tested configuration is the one the report covers.

Glass specified by thickness alone. The coating, spacer and gas move the U-value and the SHGC independently.

Operation and handing

Confirm the opening direction, the handing and the number of leaves, and say which side the handing is read from.

Handing recorded from the inside on one schedule and the outside on another.

Finish

Confirm the RAL or anodising grade, and whether the address needs a marine-grade schedule.

The finish is picked from a screen, and the coastal requirement is raised after production has started.

Hardware

Confirm handle type, locking point count, and whether the market requires key-operated locking.

Hardware assumed standard; the site then needs keyed-alike cylinders that were never on the order.

Documents with the shipment

Confirm which reports and declarations travel with the crate. A certificate is issued per configuration, not per product family.

Test documentation requested after shipment, when the report for that configuration has to be re-issued.

Screens and insect load

Confirm whether screens are part of the order. In the insect-load markets the screen is what lets the window stay open after dark.

Screens treated as an accessory and quoted separately, then the mesh does not match the frame finish.

Who confirms each part

No single party holds the whole decision. The drawing set is the one place they meet.

Buyer or developer

Opens the order: the standard the project has to meet, and the market it ships to.

Designer or architect

Sets the configuration: sizes, operation, finish and the glass build.

Structural engineer

Where the market requires it, sets the wind load the opening is rated to.

Factory

Confirms what can be built to that drawing, and issues the report for the configuration.

Everything else on the commercial side — minimum order, quotation, payment, packing and warranty — is the same on every order and sits on the commercial terms page.

Compare with the other window systems

Every system in this category on one table — the platform it shares, the opening it carries and the glazing it takes. Figures come from each system record, not retyped here.

11 window systems in the catalogue
CodeSystemPlatformGlazing options
PF-35Panoramic Fixed GlazingLaminated or low-E IGU
TT-75Tilt & Turn Windows6–24 mm single / IGU
IR-80Impact-Rated WindowsLaminated IGU, 0.38 SGP
WA-70Wood-Aluminium Windows47 dB laminated IGU
CW-60Casement Windows6–24 mm single or IGU
AC-90Acoustic Windows — this system47 dB laminated IGU
SM-60Smart Motorized Windows6–24 mm single or IGU
SW-110Six-Track Sliding Windows5+12A+5 IGU
AW-55Crank Awning WindowsTempered single pane
BP-60Burglar-Proof WindowsSingle or IGU, laminated line per SANS 1263-1
LW-70Louvre WindowsTempered single in the fixed panels

Frequently asked

It cuts typical road noise from ~70 dB outside to ~25 dB at the window — below normal conversation level.

Other systems on the same platform

All systems

Specify AC-90 for your project

Request a quote

The Certified Rw 45 dB configuration is quoted unit by unit, within 24 hours.

Prefer to talk it through?

Send a drawing or a one-line brief on WhatsApp.

+86 177 0868 3991 — quotation within 24 hours, shop drawings free in 3 working days.