Acoustic Windows
AC-90 — Certified Rw 45 dB · asymmetric glazing · sealed cavities

AC-90
For streets, airports and highway frontages that refuse to stay quiet at night.
Certified Rw 45 dB · asymmetric glazing · sealed cavities
- 10
- 6
- 35–45 days
- 15 yr
10
6
35–45 days
15 yr
What the section drawing decides
High-end custom is decided in the section drawing, not the brochure. These four layers are held to specification on every AC-90 unit we ship.
Sealed dual cavity
Opening type follows the room
Asymmetric laminated, 24-42 mm
EN ISO 10140-2 laboratory certified
Technical detail
The section, the hardware and the fixings — photographed, not rendered. This is the level of detail your drawing office specifies against and your site crew installs to, on every unit that leaves the line.
Profile cross-section
Sealed dual cavity, because an open cavity would bridge the two glass leaves and hand the sound a path straight through. The cavity is closed for the same reason the glass is asymmetric.
Sealed dual cavity
Acoustic, continuous
Asymmetric laminated, 24–42 mm
Rw 45 dB configuration






Hardware
Tilt-turn, casement or fixed: a bedroom needs the closed casement, a study can take tilt-turn. The hardware follows the room, the glass does the acoustic work either way.
Tilt-turn / casement / fixed
Set by the room, not the glass
Acoustic, continuous
Cycled as the leaf is glazed








Installation
Factory-assembled and pre-glazed, so the tolerance work is done under a roof. On site the build is a three-zone detail — air, insulation, weatherproofing — and every crate arrives with the install guide and the sealant schedule for that market.
Factory-assembled
3-zone: air / insulation / water
Per-crate install sheet
Scheduled per market






The system in short
Acoustic windows are specified to a measured figure rather than a style: asymmetric laminated glazing, sealed frame cavities and a dedicated acoustic gasket cut the sound that reaches the room. AC-90 is certified to Rw 45 dB — a 47 dB glazing unit in a dual-cavity frame — for arterial roads, airport radii and rail frontages.
Acoustic configurations pair asymmetric laminated glazing with a sealed dual-cavity frame and a dedicated acoustic gasket — the same recipe used in airport-adjacent residential projects, laboratory certified to Rw 45 dB with a 47 dB glazing unit.
The frame is a dual-cavity build and the glazing is asymmetric laminated — heavier pane on the outside, lighter on the inside, which is what breaks the resonance a matched pair would pass. Configured per position after a noise survey, quoted to the indoor target level, not to a catalogue figure.


Models and sizes
Every AC-90 ships as one of the configurations below — specify by model code in your window schedule and it quotes line by line.
AC-90 TILT
- Tilt-turn acoustic sash
- 47 dB laminated IGU
AC-90 CAS
- Hinged acoustic sash
- 47 dB laminated IGU
AC-90 FIXED
- Fixed acoustic panel
- 47 dB laminated IGU
AC-90 CORNER
- Fixed corner acoustic unit
- 47 dB laminated IGU

Specifications
- Rw 45 dB certified (47 dB glazing units)
- Asymmetric laminated, 24–42 mm total
- Sealed dual cavity, acoustic gasket
- Tilt-turn, casement or fixed
- Arterial roads, airport radius, rail frontage
- EN ISO 10140-2 laboratory certified

Material & craft
The layers held to specification on every AC-90 unit — the section drawing above, written out.

Glazing unit
A 47 dB laminated IGU with a 24–42 mm asymmetric core — the two different glass masses break the resonances a symmetric pane carries through.

Frame build
A sealed dual-cavity frame with the dedicated acoustic gasket; airtightness Class 4 is part of the acoustic build, because an unsealed joint is a leak in the rating.

Certification
Rw 45 dB laboratory certified per EN ISO 10140-2 — the figure on the data sheet is the figure from the test report.
What it's worth to you

A certified number instead of a claim: the noise survey sets the figure, the glazing mass is tuned to it, the test report proves it.
It rides the 70/75 mm platform — the quiet elevation and the standard elevation share one frame line and one schedule.
A 70 dB arterial street lands under 25 dB at the sash with the certified configuration.
Specify Acoustic Windows
Send the project location, the opening sizes and the finish. Drawings, window schedules or a specification can be attached — quoting is done against the drawings, not a price list.
Where it is specified
The sites we build this system for, and what the schedule changes in each one.
Arterial road frontages
Typical 70 dB street traffic lands under 25 dB at the sash.
Airport radius
Asymmetric laminated core tuned to the dominant noise band.
Rail frontage
Sealed cavity plus acoustic gasket for low-frequency content.
City-centre apartments
High-rise street view without the street noise.
Hospitality lobbies
Open-plan rooms next to traffic — the glazing does the zoning.
Options and finishes
Finish
Anodised Natural
Anodised Silver
Anthracite · RAL 7016
Graphite · RAL 7024
Jet Black · RAL 9005
Traffic White · RAL 9016
Cream · RAL 1015
Champagne · RAL 1019
Ash Natural
Walnut Dark
Bronze
Copper
Design features
Rw 45 dB laboratory certified (EN ISO 10140-2)
Asymmetric laminated glazing, 24–42 mm total
Sealed dual-cavity frame, acoustic gasket
Tilt-turn, casement or fixed actions
Airtightness Class 4 as part of the acoustic build
Noise-survey-driven glazing mass selection
Glass build
Two choices set what the glass does in a AC-90: which coating is on it, and what fills the cavity. The coating sets the solar figure. The gas moves the U-value and leaves the solar figure where it was — which is why the two are decided separately. The values below are published by the glass manufacturers for the build named; they are centre-of-glass figures, and the whole-window value for a configuration is read from the report that covers it.
| Build | SHGC | U, centre of glass | Where it is chosen |
|---|---|---|---|
| LoE-180, argon | 0.69 | 0.26 | High solar gain, cold climate |
| LoE-272, argon | 0.41 | 0.25 | Balanced, the usual default |
| LoE-366, argon | 0.27 | 0.24 | Solar control, west and south glass |
| LoE-366 with LoE-i89 on #4, argon | 0.27 | 0.20 | Solar control with the lowest U-value |
NFRC centre-of-glass values for a 3/4 in two-pane unit with 3 mm lites and a 13 mm argon cavity. The spacer is the third lever and behaves differently again: it works at the edge of the unit, so it shows in the whole-window value rather than here.
Full glass performance tables, including air against argon and EN 673 values →
Buying & delivery
The commercial terms behind the AC-90 — minimum order, quotation, payment, packing and warranty — are the same on every quotation and sit on the commercial terms for a certified acoustic build. Buying to resell, or to fabricate the line yourself? how an acoustic unit is supplied covers the supplier view of the same schedule.
Request a quote for this system- 35–45 days from approved shop drawings. Assembly, glazing and quality control sit inside the quoted lead time, not on top of it.
- Laboratory certified to EN ISO 10140-2 for the Rw 45 dB configuration. The assembly answers SANS 613 for wind, water and air, with the acoustic figure certified against the configured unit rather than a catalogue sample.Source documents: ISO 10140·SANS 613
- Hardware and glass schedules ship in the shop drawing package, free, within three working days of approved architectural drawings. The acoustic certificate is issued against the configured unit. Test reports are issued on request.
Documentation
Data sheet
Brochure
CAD sections & BIM families
Specification clauses
RFQ template
Confirm before the order is placed
Six items hold up an order on the AC-90 more often than anything else. None of them is decided here; each one has to be settled on the project side before the drawing set is frozen.
Rough opening, not frame size
Confirm the structural opening and the reveal build-up. The frame is ordered to the approved drawing, and the drawing is what the quotation is built from.
The opening is quoted before the render and the closing detail, then the reveal takes back the clearance.
Glass build
Confirm pane thickness, coating, spacer and cavity gas as one line. The tested configuration is the one the report covers.
Glass specified by thickness alone. The coating, spacer and gas move the U-value and the SHGC independently.
Operation and handing
Confirm the opening direction, the handing and the number of leaves, and say which side the handing is read from.
Handing recorded from the inside on one schedule and the outside on another.
Finish
Confirm the RAL or anodising grade, and whether the address needs a marine-grade schedule.
The finish is picked from a screen, and the coastal requirement is raised after production has started.
Hardware
Confirm handle type, locking point count, and whether the market requires key-operated locking.
Hardware assumed standard; the site then needs keyed-alike cylinders that were never on the order.
Documents with the shipment
Confirm which reports and declarations travel with the crate. A certificate is issued per configuration, not per product family.
Test documentation requested after shipment, when the report for that configuration has to be re-issued.
Screens and insect load
Confirm whether screens are part of the order. In the insect-load markets the screen is what lets the window stay open after dark.
Screens treated as an accessory and quoted separately, then the mesh does not match the frame finish.
Who confirms each part
No single party holds the whole decision. The drawing set is the one place they meet.
Buyer or developer
Opens the order: the standard the project has to meet, and the market it ships to.
Designer or architect
Sets the configuration: sizes, operation, finish and the glass build.
Structural engineer
Where the market requires it, sets the wind load the opening is rated to.
Factory
Confirms what can be built to that drawing, and issues the report for the configuration.
Everything else on the commercial side — minimum order, quotation, payment, packing and warranty — is the same on every order and sits on the commercial terms page.
Compare with the other window systems
Every system in this category on one table — the platform it shares, the opening it carries and the glazing it takes. Figures come from each system record, not retyped here.
| Code | System | Platform | Glazing options |
|---|---|---|---|
| PF-35 | Panoramic Fixed Glazing | Laminated or low-E IGU | |
| TT-75 | Tilt & Turn Windows | 6–24 mm single / IGU | |
| IR-80 | Impact-Rated Windows | Laminated IGU, 0.38 SGP | |
| WA-70 | Wood-Aluminium Windows | 47 dB laminated IGU | |
| CW-60 | Casement Windows | 6–24 mm single or IGU | |
| AC-90 | Acoustic Windows | 47 dB laminated IGU | |
| SM-60 | Smart Motorized Windows | 6–24 mm single or IGU | |
| SW-110 | Six-Track Sliding Windows | 5+12A+5 IGU | |
| AW-55 | Crank Awning Windows | Tempered single pane | |
| BP-60 | Burglar-Proof Windows | Single or IGU, laminated line per SANS 1263-1 | |
| LW-70 | Louvre Windows | Tempered single in the fixed panels |
Acoustic Windows installed

Frequently asked
It cuts typical road noise from ~70 dB outside to ~25 dB at the window — below normal conversation level.
Other systems on the same platform
All systems



Specify AC-90 for your project
The Certified Rw 45 dB configuration is quoted unit by unit, within 24 hours.