Quiet interior behind an acoustic glazing wall

Specifying

Acoustic glazing: how 45 dB is actually achieved

Adam Windows Team • September 23, 2026

The 45 dB figure is a system property, not a glass property. AC-90 is the acoustic glazing line that pairs a 47 dB asymmetric laminated IGU (24–42 mm total) with a sealed dual-cavity frame and a dedicated acoustic gasket, certified to Rw 45 dB to EN ISO 10140-2. The frame has to be as quiet as the glass — air leaking past the sash bypasses the glazing entirely, which is why Class 4 airtightness is part of the acoustic build rather than a separate specification line.

Short answer

Acoustic glazing reaches 45 dB as a system, not as a pane: an asymmetric laminated IGU, a wider cavity than a thermal build wants, a dual-sealed frame and a dedicated acoustic gasket. The number belongs to the assembled unit, so a 45 dB glass in a standard frame will not deliver 45 dB in the wall. Specify the tested configuration and ask for the report that names it.

Why the glass alone cannot deliver the number

Sound takes the path of least resistance. A 47 dB pane in a frame that leaks at the meeting stile or the sill performs at the leak, not at the pane — the measured performance of the whole unit is set by its weakest member, and on windows the weakest member is usually a joint. The AC-90 build attacks the problem in three places: the glazing (asymmetric laminated core), the frame (a sealed dual cavity, so the sound cannot tunnel through the profile), and the gasket line (a dedicated acoustic compression, not the weather seal doing double duty).

The glazing, asymmetric on purpose

Asymmetry is the working principle: two panes of the same thickness in coincidence amplify the sound at a narrow band, so the build pairs different masses with an interlayer — a laminated unit from 24 to 42 mm total where the panes do not mirror each other. The mass selection follows the noise survey, not the style: arterial traffic is mid-band, an airport radius is dominated by the low-band rumble, and a rail frontage is the hardest case, because the low frequency wants more mass and a sealed cavity to keep it out. The survey sets the total mass and the interlayer, and the certification is run on that configuration.

Quiet glazing behind the water at night

What 45 dB acoustic glazing means at the window

The field case on the schedule is the arterial road: a street measuring around 70 dB at the façade lands under 25 dB at the sash once the AC-90 unit is in place — the difference is the 45 dB the certification names. That is the number that lets the bedroom sit on the road and the meeting room sit on the rail line. The build runs as tilt-turn, casement, fixed, or the fixed corner unit, so the acoustic line follows the opening the drawing already has instead of the other way round.

The 45 dB build, line by line

ElementWhat it isWhy it is in the build
Outer liteLaminated, the heavier massThe mass and the damping layer
CavityThe wider air gapDecouples the two lites
Inner liteThe lighter, clear sideCompletes the asymmetric pair
Frame cavityDual-cavity, thermally brokenThe frame is the flanking path
Seal classClass 4 airtightnessAir is the carrier of the low band

Where the rest of the range picks it up

  • PF-35 ACOUSTIC: the panoramic fixed line carries the 47 dB laminated IGU for the view-first elevation that cannot give up the glass.
  • WA-70 ACOUSTIC: wood-aluminium — timber mass inside, bonded aluminium outside — the certified 45 dB build for the design-led street frontage.
  • SM-60 smart operation: the drive closes the acoustic sash on the rain sensor and the schedule, which is how the 45 dB stays in the room instead of being voided by an open window at 6 pm.
Bedroom wall on a slim dark frame, quiet glazing

Reading the rating on the schedule

The 45 dB figure on the schedule is a rating of the configured unit — the glazing, the frame, the seal class, tested as one — and it is stated with the configuration, not alone. A rating without the build behind it is a number the project cannot hold the supplier to, because the same unit at a different seal class is a different number, and the schedule is where the two are pinned together.

The reading the reviewer wants is the build line first and the value second: the asymmetric laminated IGU, the dual-cavity frame, the airtightness class, and then the rating the set produces. Acoustic glazing is specified that way on the export schedule, and the document pack carries the measurement reference for the configured set, so the value and the build travel together to the site.

Where acoustic glazing is specified first

The elevation, not the room, usually carries the call, and the usual first calls are:

  • The road frontage: the elevation facing the traffic lane carries the high build.
  • The airfield radius: the zone mapping drives the glazing call per elevation.
  • The party wall to a louder use: the interior line becomes the glazing line.
  • The bedroom and the study, on any exposure: the room function sets the target.
  • The terrace door: the opening path is the weak point, and the door is rated with the window.

The flanking paths, and the honest number

The honest number on the schedule is the unit rating, and the honest note is the flanking: the wall around the window, the door in the same room, the mounting, all carry sound the glass does not see. The specification states the glazing rating and names the flanking path as the site responsibility, which is the split the installer and the acoustician both sign, and it keeps the 45 dB build from being quoted as a room promise it was not worked to deliver.

Frequently Asked Questions

Is Rw 45 the same as 45 dB quieter?

It is the laboratory rating of the unit. The field result is set by the survey and the installation — the Class 4 airtightness of the build is what keeps the field close to the lab.

Can the acoustic build take low-E and argon?

Yes — the laminated core sits in a standard IGU, so the solar-control and thermal options apply on top of the acoustic configuration.

Which action suits the loudest frontage?

Fixed, where the drawing allows it; otherwise tilt-turn, because the multi-point compression keeps the gasket line tight through the seasons.

Is the 45 dB figure a reduction or a rating?

A rating of the configured unit, produced to the measurement procedure the schedule names. The reduction the room experiences also depends on the flanking paths — the wall, the door, the mounting — which is why the build, not the number alone, is specified.

Can the acoustic build carry the solar call at the same time?

Yes — the coating and the mass are independent variables on the same lite, and the schedule carries them as separate lines. The combination is worked per configuration, like any other glazing call.

Does acoustic glazing cost more than laminated glass alone?

It usually does, because acoustic glazing is a build rather than a pane: the laminated core is paired with a different cavity and often unequal glass thicknesses, and the frame gasket changes with it. The figure to compare is the Rw of the whole unit.

Standards cited

The acoustic numbers are laboratory figures from the ISO series, not field measurements. The publisher page is here so the test route can be confirmed.

  • ISO 10140 — laboratory measurement of sound insulation of building elements. International Organization for Standardization

The systems this applies to

Prefer to talk it through?

Send a drawing or a one-line brief on WhatsApp.