A window that passes in the United States and a window that passes in Australia are proved by two different tests. AAMA is the North American route: the performance class sets the air, water and structural targets, and the unit is rated as a class — R, LC, CW or AW — before it is placed. AS 2047 is the Australian route: the unit is tested to the site wind pressure the project sets, with the results tied to that pressure. The job is the same, the paperwork is not, and an order that ships to both carries both.

The AAMA route, class-first

In North America the unit is tested to the fenestration standard and given a performance class — R, LC, CW or AW — that bundles an air-infiltration limit, a water-penetration pressure, a structural pressure and a size limit for that class. The class is the headline: an AW unit is a different product from an R unit, and the architect specifies the class before the size. The test is on the rated size, and a larger unit can fall out of the class it passed in.

The AS 2047 route, pressure-first

In Australia the unit is tested to the site wind pressure, and the air, water and structural results are reported against that pressure — the design wind pressure the project sets from AS 1170.2, not a fixed class. That makes the report project-tied: the same frame can pass at one site wind pressure and need a heavier build at another. The reach is set by the tested size, and the impact case (AS 2208) sits on top for the cyclone region.

Australian residential glazing, AS 2047 basis

Why both, on one order

An order that ships to a US project and an Australian project carries two test columns on one platform, because the frame does not change for the market — the glazing, the hardware and the paperwork do. The drawing office runs the unit through the route the destination sets: the AAMA class or the AS 2047 project pressure, with the impact and cyclone additions where the region requires them. One supplier, two reports, one product.

Dusk elevation, certified unit in place

The two routes, line by line

LineThe AAMA routeThe AS 2047 route
The standardThe North American setThe Australian standard
The entry pointThe characteristic, class-firstThe pressure case, pressure-first
The resultThe class per characteristicThe pressure, the cycle, the case
The reportThe AAMA recordThe AS record
The destinationThe North American reviewerThe Australian reviewer

What to put on the schedule

  • The destination market, because it sets the test route — AAMA class in the US, AS 2047 project pressure in Australia.
  • The class or the design wind pressure the project requires, stated on the schedule.
  • The tested size and its limit, so the unit is inside the reach the report covers.
  • The impact or cyclone addition where the region requires it: Miami-Dade in the US, AS 2208 in Australia.

The two test reports, side by side

The AAMA report and the AS 2047 report are two records of two different test orders: the AAMA line runs the characteristics in the class-first sequence, the AS line runs the pressure cases in the pressure-first order, and each report is the record of the test as it was run, to the limits of the standard it answers. The unit that meets both is built to the higher of the two at each characteristic, and the pack carries the two reports — one per route, one per destination, and the schedule line states which report covers which market.

The reading for the export order: the reports are documents, not decorations. The AAMA report travels to the North American reviewer, the AS report to the Australian one, and the same window on the same container is read against the two records at the two destinations. The order pack is where the two are split, and the split is per the destination the crate ships to, not per the project the drawing came from.

A worked example: one order, two destinations

The order is one container, split: the majority of the units to the US coast, the remainder to an Australian site on the same project family. The frame line is one — the profile, the finish, the hardware — and the test pack is two: the AAMA line for the US units, the AS 2047 line for the Australian units, each report covering the units it ships with. The crate list keys each crate to the destination, and the document pack follows the key.

The worked check at the yard: the US crate opens to the AAMA report, the Australian crate to the AS report, and the crate count agrees with the split on the schedule. One order, two standards, two reports, one container — and the schedule is the page where the four are told apart, line by line, before the first crate is loaded.

The pack split is the document the customs line reads too: the two destinations, the two packs, the crate key that ties each crate to its report. The worked check travels the full chain — the yard, the port, the destination — and the two reports are the lines the chain is checked against, at every step, per the schedule. The order family is one drawing, two columns, two reports, and the schedule is the page the family is read from, the line that holds the split together from the first cut to the last crate.

Frequently Asked Questions

Can an AAMA-rated unit go to Australia?

It would still have to be tested to AS 2047 for that project, because the Australian route is project-pressure-tied. The frame can be the same; the report is separate.

What does the AAMA class actually set?

A bundled air, water, structural and size target for the class — R, LC, CW or AW — that the unit is rated against. The architect specifies the class, then the size within it.

Is AS 2047 harder than AAMA?

Neither is harder in the abstract; they are different routes. AS 2047 ties the result to the site wind pressure, so a high-pressure site pushes the build further than a nominal class would.

Can one test report cover both markets?

No — the two standards test in different orders and to different limits, and the report is the record of the test as run. The unit can be built to meet both, and the pack carries the two reports, one per route.

Is the dual-standard build more expensive than either alone?

The build is the higher of the two at each characteristic, and the cost is the difference from the lower route — stated on the quotation as the dual line, so the buyer sees the price of the extra coverage before the order is placed.

Standards cited

This is a comparison of two rating systems, so both are linked at source: AS 2047 at Standards Australia, the North American standard at FGIA.

  • AS 2047:2014 — windows and external glazed doors, performance and labelling. Standards Australia
  • AAMA/WDMA/CSA 101/I.S.2/A440 — North American Fenestration Standard, performance class and grade. FGIA (formerly AAMA)
  • AS/NZS 2208:2021 — safety glazing materials in buildings. Standards Australia
  • AS/NZS 1170.2:2021 — structural design actions, part 2: wind actions. Standards Australia